Background

Services

Torr Page

Invisible Threats,
Visible Safety

Fire & Gas Protection for Sarawak's O&G Industry

As a business owner, ensuring the safety of your employees and property from hazardous gases is crucial. Our Gas Detection Solutions are designed to provide peace of mind, knowing your facility is equipped to detect and respond to any gas-related incidents promptly.

You work hard to maintain a safe workplace. Let us help you keep it that way.

Fixed Gas Detector Portable Gas Detector
The Challenge

You need more than compliance. You need a partner who understands the real consequences of gas detection failures — and designs systems that genuinely protect your people and assets.

  • Outdated detection systems that fail to meet current NFPA or PETRONAS TSP standards
  • Inconsistent maintenance leading to false alarms or missed detections
  • Lack of integrated detection-to-response logic
  • Non-compliance risks leading to shutdown, fines, or audit failures
Our Approach

Customised Gas Detection,
Not Off-the-Shelf

Every facility has a unique gas risk profile. We start with yours — designing systems that are right for your environment, your team, and your regulatory obligations.

01
Hazard-Specific Design
Systems engineered around your specific flammable and toxic gas inventory, ignition sources, and layout — not a generic template.
02
Full Lifecycle Support
From FEED through commissioning to planned maintenance — we stay with you at every stage of the system's life.
03
Compliance Guaranteed
All designs meet NFPA 72, MS 1514, DOSH requirements and PETRONAS TSP — with full documentation for audit readiness.
What We Deliver

Integrated Fire & Gas
Protection Systems

Four specialist disciplines — delivered together as a seamless, integrated solution or as standalone services based on your needs.

Fire Alarm & Detection Systems
Early detection. Fast response. Life safety first.

We design and install addressable and conventional fire alarm systems engineered for complex industrial environments — from single-zone control panels to facility-wide integrated FGS networks.

  • Addressable & conventional fire alarm panels (Kidde, Honeywell, Siemens)
  • Smoke, heat, flame & multi-sensor detectors
  • Manual call points, sounders & visual alarms
  • Fire alarm control panel programming & commissioning
  • Integration with DCS / SCADA / PA systems
  • Full NFPA 72 compliance & documentation
Gas Detection Solutions
Detect threats before they become emergencies.

Fixed and portable gas detection systems for flammable, toxic, and oxygen-deficient atmospheres. Designed and positioned based on gas dispersion modelling and facility layout analysis.

  • Flammable gas detectors (catalytic bead, IR point, open path)
  • Toxic gas detectors (H2S, CO, SO2, NH3)
  • Oxygen deficiency monitors
  • Gas dispersion modelling & detector placement study
  • Integration with FGS panels and ESD systems
  • PETRONAS TSP & IEC 60079 compliant installation
Fire Suppression Systems
The right suppression agent for your environment.

We design and install suppression systems using the most appropriate agent for your facility — whether protecting sensitive equipment, process areas, or personnel-occupied spaces.

  • FM200 (HFC-227ea) clean agent systems
  • NOVEC 1230 (FK-5-1-12) — low GWP clean agent
  • CO2 total flooding & local application
  • Wet chemical & dry powder systems
  • Foam-based suppression (AFFF, FFFP)
  • Sprinkler & deluge systems (NFPA 13 compliant)
Fire Prevention & Fireproofing
Passive protection that never sleeps.

Beyond active detection and suppression — passive fire protection and prevention measures that limit fire spread, protect structural integrity, and reduce ignition risk.

  • Intumescent coating & fireproofing application
  • Fire dampers, barriers & penetration sealing
  • Room integrity testing (door fan test — ISO 14520)
  • Fire risk assessment & HAZOP support
  • Foam sampling & testing (PETRONAS STP-OP-081)
  • Fire drill planning & emergency response support
Our Process

How We Deliver Your
Fire & Gas Solution

A structured, transparent process from first conversation to long-term support — so you always know what's happening and why.

1
Consultation
Site visit & requirements scoping. We learn your facility, hazards, and regulatory context.
2
Risk Assessment
Fire & gas hazard mapping, detector placement study, gap analysis against applicable standards.
3
System Design
Custom P&IDs, equipment selection, FEED / detailed engineering — submitted for client & regulator approval.
4
Installation
Certified installation by our qualified engineers & technicians, with full HSE compliance on-site.
5
Commissioning
Factory acceptance test (FAT), site acceptance test (SAT), and regulatory sign-off with full handover documentation.
6
Maintenance
Planned preventive maintenance, corrective work, and 24/7 support to keep your system performing.
System Selection Guide

Choosing the Right
Suppression Agent

Not all suppression agents are equal. The right choice depends on your asset type, occupied status, environmental obligations, and fire risk profile. Use this guide — or ask our engineers.

Criteria FM200 Popular NOVEC 1230 Low GWP CO2 Foam (AFFF) Dry Powder
Safe for occupied spaces Evacuate first Limited
Zero equipment residue
Suitable for electronics / IT With care
Offshore / marine rated
Low global warming potential High GWP GWP = 1 GWP = 0 Medium
Large area coverage Limited Limited
Best for liquid / pool fires
Applicable standard NFPA 2001 / ISO 14520 NFPA 2001 / ISO 14520 NFPA 12 NFPA 11 NFPA 17

Not sure which system fits your facility? Talk to our engineers → We provide no-obligation system recommendations.

Compliance Framework

Standards We Work To

All Torr Energy fire & gas solutions are designed and installed in compliance with the following international and Malaysian standards.

NFPA 72
National Fire Alarm & Signaling Code
Design and installation of fire alarm, detection, and emergency communication systems.
NFPA 13
Installation of Sprinkler Systems
Standard for the design, installation, and testing of automatic sprinkler systems.
NFPA 2001
Clean Agent Fire Extinguishing Systems
Covers FM200, NOVEC 1230 and other clean agent suppression system design.
NFPA 12
Carbon Dioxide Extinguishing Systems
Design, installation and maintenance of CO2 total flooding and local application systems.
MS 1514
Malaysian Standard — Fire Detection
Local Malaysian standard governing fire detection and alarm systems for buildings and facilities.
PETRONAS TSP
PETRONAS Technical Standards
Proprietary engineering standards applicable to all PETRONAS-operated facilities and contractors.
ISO 14520
Gaseous Fire Extinguishing Systems
International standard for design, installation and maintenance of clean agent suppression systems.
IEC 61511
Safety Instrumented Systems (SIS)
Functional safety standard for fire & gas systems as part of the safety instrumented layer.
DOSH Malaysia
Department of Occupational Safety & Health
Malaysian regulatory framework governing workplace fire safety and explosion prevention.
Our Credentials

Certified, Accredited &
Independently Verified

Our certifications aren't just logos. They represent independently verified competence — and give you the assurance that our work meets global benchmarks.

IECEx Certified
International certification for inspection & maintenance of equipment in explosive atmospheres
UKAS Accredited
UK Accreditation Service recognition of our management systems and technical competence
SME100 Award
Recognised as one of Malaysia's top fast-moving SME companies
Guardian Certified
Independent third-party certification validating our quality and service standards
PETRONAS Registered Vendor
Approved vendor for PETRONAS and its production-sharing contract operators
Why Torr Energy

The Partner Built
for This Industry

We know Sarawak's O&G landscape — the clients, the standards, the on-site realities. That local depth, combined with international certification, makes Torr the right choice.

Turnkey Capability
Design, supply, install, commission and maintain — all from one partner
Local Presence
4 branches across Sarawak means fast response and site mobilisation
Audit-Ready Docs
Full as-built drawings, test certificates, and compliance records delivered on every job
Long-Term Support
Planned maintenance contracts that keep your system performing year after year

Torr Energy's team designed and installed our FGS upgrade across three process modules — on time, within budget, and with zero HSE incidents. Their documentation package was the most comprehensive we've received from any contractor.

MR
Maintenance Superintendent
Offshore Platform Operator, Sarawak
Recent Project References
  • FGS panel upgrade — FPSO, offshore Sarawak
  • NOVEC 1230 suppression — MCC room, Bintulu LNG
  • Gas detection replacement — Drilling rig, South China Sea
  • Foam sampling & testing — Tank farm, PETRONAS Dagangan
  • Room integrity test — Server room, onshore oil terminal

Ready to Upgrade Your
Fire & Gas Protection?

Talk to our engineers. We'll assess your facility and recommend the right solution — at no obligation.

TAKE THE NEXT STEP IN SAFETY

We’re here to support you in creating a safer, more efficient work environment. Let’s work together to build a solution that fits your needs perfectly. Contact Us today for a consultation or to learn more about how we can help you achieve your safety goals.

Email

torr.energy@gmail.com

Contact

+085 665454 | +085 628008

INQUIRE